Two pMUT sensors integrated in an ultrasound probe demonstrator.
Two pMUT sensors integrated in an ultrasound probe demonstrator.
Source: imec

Ultrasound sensor measures blood pressure

Imec presents a proof-of-concept for determining arterial stiffness, a risk marker for cardiovascular diseases such as stroke and heart failure, and monitoring blood pressure. They use an ultrasound sensor to measure the central pulse wave velocity.

Measuring pulse wave velocity closer to the heart is also a more reliable proxy for blood pressure than existing peripheral measurements. The method has the potential to improve the practicality of clinical cardiovascular risk assessment in the GP’s office because the ultrasound sensor could be scaled to the size of a portable or wearable device.

Cardiovascular disease (CVD) is globally among the leading causes of death. Early identification of individuals at risk allows for early intervention. Arterial stiffness is an independent predictor of CVD and a marker for developing hypertension. The recommended practice to assess arterial stiffness is by measuring the arterial pulse wave velocity (PWV). However, because PWV measures often require invasive or less accessible imaging methods, clinicians prefer a cuff-based blood pressure measure to assess CVD risk. Nevertheless, a more practical central PWV method would add value over conventional cuff-measured blood pressure to determine CVD risk. Without a way to easily screen a large population for arterial stiffness, many individuals remain undiagnosed.

“We have developed a promising method to determine PWV using an ultrasound sensor and a novel data analysis approach. The ultrasound sensor captures the heartbeat of the patient in the neck and the algorithms subsequently extract the features necessary to calculate PWV. PWV can then be used to determine cardiovascular function indicators, such as arterial stiffness and blood pressure,” said Fabian Beutel, Biomedical R&D Engineer and PhD candidate at KU Leuven.

Moreover, the researchers showed that a central PWV (closer to the heart) correlates more reliably with blood pressure than a peripheral measurement. “Our approach holds great clinical potential for continuous CVD monitoring and longitudinal unobtrusive blood pressure measurements, since imec’s ultrasound sensor technology can be reduced to fit the size of a portable or wearable device, such as a smartphone or patch,” said Xavier Rottenberg, Fellow Wave-Based Sensors and Actuators.

Signal traces obtained by two piezoelectric Micromachined Ultrasound Transducer...
Signal traces obtained by two piezoelectric Micromachined Ultrasound Transducer (pMUT) sensors.
Source: imec

A small-scale cohort involving 10 people featuring a wide range of blood pressure values from normal to elevated demonstrated the proof-of-concept of this novel method to measure central PWV and estimate blood pressure. The test confirmed that measuring PWV centrally correlated better with arterial stiffness and blood pressure than the traditional peripheral method using an ECG and an optical measurement at a distance from the heart. Unlike with conventional methods, the new blood pressure estimates are within the accuracy limits used in the IEEE blood pressure validation standard.

“This technology and algorithm can be scaled to any device that fits the application: portable, wearable and even ingestible devices. We’re looking for companies to join us in the research and development of this technology and unlock new medical applications,” Carlos Agell, Health Solutions Program Manager.

Subscribe to our newsletter

Related articles

Skin patch for early warning of strokes

Skin patch for early warning of strokes

Engineers developed a soft and stretchy ultrasound patch that can be worn on the skin to monitor blood flow through major arteries and veins deep inside a person’s body.

Necklace detects abnormal heart rhythm

Necklace detects abnormal heart rhythm

A necklace which detects abnormal heart rhythm will be showcased for the first time on EHRA Essentials 4 You, a scientific platform of the European Society of Cardiology (ESC).

Using mhealth for detecting atrial fibrillation

Using mhealth for detecting atrial fibrillation

A new study highlights the feasible use of mhealth devices to help with the screening and detection of atrial fibrillation.

A personalized exosuit for walking

A personalized exosuit for walking

A new approach in which robotic exosuit assistance can be calibrated to an individual.

‘Smart’ shirt keeps tabs on the heart

‘Smart’ shirt keeps tabs on the heart

A flexible carbon nanotube fibers can be incorporated into clothing to function as wearable health monitors.

Touch-sensing glove detects and maps tactile stimuli

Touch-sensing glove detects and maps tactile stimuli

Engineers have designed a new touch-sensing glove that can “feel” pressure and other tactile stimuli. The design could help restore motor function after stroke.

Machine learning improves when social factors are included

Machine learning improves when social factors are included

Machine learning can accurately predict cardiovascular disease and guide treatment — but models that incorporate social determinants of health better capture risk and outcomes for diverse groups.

Printable biosensors could make surgery safer

Printable biosensors could make surgery safer

Researchers have developed fully printable biosensor made of soft bio-inks interfaces with a pig heart.

Robot-assisted surgery: Putting the reality in VR

Robot-assisted surgery: Putting the reality in VR

Cardiac surgeons may be able to better plan operations and improve their surgical field view with the help of a robot.

Popular articles

Subscribe to Newsletter