Schematic of neonatal wearable device for detecting jaundice and vitals.
Schematic of neonatal wearable device for detecting jaundice and vitals.
Source: Yokohama National University

Wearable monitors jaundice-causing bilirubin in newborns

Researchers at Yokohama National University have developed the first wearable devices to precisely monitor jaundice, a yellowing of the skin caused by elevated bilirubin levels in the blood that can cause severe medical conditions in newborns.

Jaundice can be treated easily by irradiating the infant with blue light that breaks bilirubin down to be excreted through urine. The treatment itself, however, can disrupt bonding time, cause dehydration and increase the risks of allergic diseases. Neonatal jaundice is one of the leading causes of death and brain damage in infants in low- and middle-income countries.

To address the tricky balance of administering the precise amount of blue light needed to counteract the exact levels of bilirubin, researchers have developed the first wearable sensor for newborns that is capable of continuously measuring bilirubin. In addition to bilirubin detection, the device can simultaneously detect pulse rate and blood oxygen saturation in real time.

The team was Led by Hiroki Ota, associate professor of mechanical engineering in Yokohama National University's Graduate School of System Integration, and Shuichi Ito, professor of department of Pediatrics in Yokohama City University's Graduate School of Medicine. 

"We have developed the world's first wearable multi-vital device for newborns that can simultaneously measure neonatal jaundice, blood oxygen saturation and pulse rate," Ota said, noting that jaundice occurs in 60 to 80% of all newborns. "The real-time monitoring of jaundice is critical for neonatal care. Continuous measurements of bilirubin levels may contribute to the improvement of quality of phototherapy and patient outcome."

Photo
Actual wearable device.
Source: Yokohama National University

Currently, medical professionals use handheld bilirubinometers to measure bilirubin levels, but there is not a device that can simultaneously measure jaundice and vitals in real time. "In this study, we succeeded in miniaturizing the device to a size that can be worn on the forehead of a newborn baby," Ota said. "By adding the function of a pulse oximeter to the device, multiple vitals can easily be detected."

Held to the baby's forehead by a silicone interface, the device has a lens capable of efficiently transmitting lights to neonatal skin via battery-powered light-emitting diodes, commonly known as LEDs. "At the present stage, coin cell batteries are used, and the overall shape is very thick," Ota said. "In the future, it will be necessary to further reduce the thickness and weight by using thin-film batteries and organic materials."

The researchers tested the device on 50 babies, and they found that the device is not currently accurate enough to suffice for clinical decision-making. According to Ota, they will reduce the thickness and increase the flexibility of the device, as well as improve the silicone interface to facilitate better skin contact.

In the future, the researchers plan to develop a combined treatment approach that pairs a wearable bilirubinometer with a phototherapy device to optimize the amount and duration of light therapy based on continuous measurements of bilirubin levels.

The team published their results in Science Advances.

Subscribe to our newsletter

Related articles

Sticker detects cystic fibrosis in newborn's sweat

Sticker detects cystic fibrosis in newborn's sweat

Researchers have developed a novel skin-mounted sticker that absorbs sweat and then changes color to provide an accurate, easy-to-read diagnosis of cystic fibrosis within minutes.

A new medical device for monitoring vital signs

A new medical device for monitoring vital signs

A new device consisting of a 3D-printed wristband can remotely monitor patients' vital signs, such as body temperature, oxygen saturation, pulse, and respiratory rate.

Micro-supercapacitors to self-power wearables

Micro-supercapacitors to self-power wearables

A stretchable system that can harvest energy from human breathing and motion for use in wearable health-monitoring devices may be possible.

Powering wearable sensors through human motion

Powering wearable sensors through human motion

Researchers have harvested kinetic energy that is produced by a person as they move around.

Wearable pressure-sensitive devices

Wearable pressure-sensitive devices

Scientists have devised solutions to the problems presented in constructing wearable pressure-sensitive sensors.

Wearable sensor for patients with inflammatory bowel disease

Wearable sensor for patients with inflammatory bowel disease

Researchers have designed a wearable device that monitors sweat for biomarkers that could signal flare-ups of inflammatory bowel disease (IBD).

Withings’ wearable receives medical CE marking

Withings’ wearable receives medical CE marking

Withings announced the European availability of ScanWatch after receiving the CE marking for medical devices.

Wearable offers new option for monitoring heart health

Wearable offers new option for monitoring heart health

An invention may turn one of the most widely used materials for biomedical applications into wearable devices to help monitor heart health.

Wearable devices set to diagnose preeclampsia or epilepsy

Wearable devices set to diagnose preeclampsia or epilepsy

Transforming how common health conditions are diagnosed using point-of-care and wearable bio diagnostic devices is the goal of a new University of South Australia project.